FLOOR SIZE
Wall to Wall – 90' x 210' Bleachers Extended – 67' x 150'
Due to ice floor piping, semi-trucks are not allowed on the arena floor at any time.
LOADING AREA
Load-in for the arena is accomplished through a 15' x 15' roll-up door in the southwest corner of the arena. Any equipment requiring a loading height greater than 14’ must be advanced in order to adjust the interior curtain clearance. Loading for additional trucks is possible through three (2) 13’ 6" H x 10’ W doors in a backstage area located 40’ south of the main load-in door. However, direct passage to the arena from this location is restricted by a width of 6’ 10".
SEATING CAPACITIES
Upper Level - 3,520 Club Level - 476 Lower Level - 6,773 Floor - 1,316 Disabled Seating - 178 In the Round - 11,766 South end Stage - 8,063 3/4 House - 5,940 Half House - 4,833 Broadway Configuration - 2,460 Basketball - 10,768
RIGGING INFORMATION
East/west beams on 30’ centers run the width of the arena.
All rigging steel is 87’ above the arena floor.
Each beam can hold a maximum weight of 20,000 pounds, with a per point maximum of 5,000 pounds. Obstructions:
ELECTRICAL INFORMATION
Show Power – Southwest arena wall 1- 600 amp, 208 volt, 5 wire service 1- 200 amp, 208 volt, 5 wire service 1- 400 amp, 208 volt, 5 wire service 1- 200 amp, 208 volt, 5 wire service The 600 amp and one 200 amp disconnect are powered from a separate substation than the 400 amp and remaining 200 amp services.
DRESSING ROOMS
(4) Dressing Rooms in SE hallway
(1) Green Room in SE hallway
(1) Production Room in SE hallway
(2) Locker Rooms on North side of building
Other meeting rooms and team rooms may be available for rental as needed for additional office or reception space.